Portable 10" Screen VET Veterinary Patient Monitor with Multi-Parameter Vital Signs, ECG, NIBP, RESP, TEMP, SPO2, and PR - Ensure Optimal Care for Your Furry Patient Anytime and Anywhere

SKU: 800258-7031

Price:
Sale price$334.19

Description

  • 10 inch color high resolution TFT display,for easy-to-view vital signs monitoring at a glance,for veterinarian convenience operation.
  • Can be arbitrarily set the alarm limit, automatic sound and light alarm
  • Anti-movement, anti-defibrillation,anti electrosurgical interference
  • Drug solubility calculation function, Arrhythmia analysis function
  • Fanless design,quiet,energy-saving and clean,which reduces the possibility of cross-infection.
  • Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure.
  • Portable and ergonomic design with classical handle, with long life rechargeable battery, it can be easily transfer to anywhere in need.
  • It can be connected to the central monitoring system via wired network so as to form a network monitoring system.

PM10 is a Professional Veterinary Monitor has abundant monitoring functions and can be used for monitoring of cat,dog and other animals.User may select different parameter configurations according to different requirements.This device can monitor such parameters as ECG,RESP, SpO2, PR,NIBP,TEMP, etc.

Application:Widely used in the Animals Clinic,Hospital,Suitable for cats,canines and other big animals.

Standard configuration:

ECG, NIBP, SPO2, TEMP, RESP,PR

Specification:

ECG

Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection:I, II, III, avR, avL, avF, V,

Waveform:2 ch

Lead mode:3 Leads ( R, L, F or RA, LA, LL)

Lead selection:I, II, III,

Waveform:1 ch

Gain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

HR and Alarm 

Range: 

Adult:15 ~ 300 bpm

Neo/Ped:15 ~ 350 bpm

Accuracy:± 1% or ± 1bpm,which great

Resolution:1 bpm

Sensitivity:> 200 (uV P-P)

Differential Input Impedance:> 5 MΩ

RESPARATION:

Method:Impedance between R-F(RA-LL)

Differential Input Impedance:>2.5 MΩ

Measuring Impedance Range:0.3~5.0Ω

Base line Impedance Range:0 – 2.5  KΩ

Bandwidth:0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range 

Adult:0 ~ 120 rpm

Neo/Ped:0 ~ 150 rpm

Resolution:1 rpm

Accuracy:±2 rpm

Apean Alarm:10 ~ 40 S

NIBP

Method:Oscillometric

Mode:Manual, Auto, STAT

Measuring Interval in AUTO Mode

 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode:5 Min

Pulse Rate Range:40 ~ 240 bpm

Alarm Type:SYS, DIA, MEAN

Measuring and alarm range:   

Adult Mode

SYS :40 ~ 270 mmHg

DIA :10 ~ 215 mmHg

MEAN:20 ~ 235 mmHg

Pediatric Mode

SYS:40 ~ 200 mmHg

DIA:10 ~ 150 mmHg

MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS:40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Overpressure Protection

Adult Mode:297±3 mmHg

Pediatric Mode:240±3 mmHg

Neonatal Mode:147±3 mmHg

SpO2

Measuring Range:0 ~ 100 %

Alarm Range:0 ~ 100 %

Resolution:1 %

Accuracy:     

70% ~ 100%  ±2 %

0%  ~  69%  unspecified

Actualization interval:about 1 Sec.

Alarm Delay:10 Sec.

Pulse Rate

Measuring and Alarm Range:0~254bpm

Resolution:1bpm

Accuracy:±2bpm

I.5TEMP measurement:

Channel:1

Measuring and Alarm Range:0 ~ 50 °C

Resolution:0.1°C

Accuracy:±0.1°C

Actualization interval:about 1 Sec.

Average Time Constant:< 10 Sec.